Search results

Filters

  • Journals
  • Date

Search results

Number of results: 9
items per page: 25 50 75
Sort by:

Abstract

Measurement data obtained from Weigh-in-Motion systems support protection of road pavements from the adverse phenomenon of vehicle overloading. For this protection to be effective, WIM systems must be accurate and obtain a certificate of metrological legalization. Unfortunately there is no legal standard for accuracy assessment of Weigh-in-Motion (WIM) systems. Due to the international range of road transport, it is necessary to standardize methods and criteria applied for assessing such systems’ accuracy. In our paper we present two methods of determining accuracy of WIM systems. Both are based on the population of weighing errors determined experimentally during system testing. The first method is called a reliability characteristic and was developed by the authors. The second method is based on determining boundaries of the tolerance interval for weighing errors. Properties of both methods were assessed on the basis of simulation studies as well as experimental results obtained from a 16-sensor WIM system.
Go to article

Abstract

Paper deals with the new localizer GLOP2 designed for detection of the miners trapped in underground hard coal mines. The results of a field test conducted in coal mine BOBREK show that the presented localizer allows for efficient measurement of the distance between a trapped miner and the rescuer in the range of up to 15 m.
Go to article

Abstract

Minimally invasive procedures for the kidney tumour removal require a 3D visualization of topological relations between kidney, cancer, the pelvicalyceal system and the renal vascular tree. In this paper, a novel methodology of the pelvicalyceal system segmentation is presented. It consists of four following steps: ROI designation, automatic threshold calculation for binarization (approximation of the histogram image data with three exponential functions), automatic extraction of the pelvicalyceal system parts and segmentation by the Locally Adaptive Region Growing algorithm. The proposed method was applied successfully on the Computed Tomography database consisting of 48 kidneys both healthy and cancer affected. The quantitative evaluation (comparison to manual segmentation) and visual assessment proved its effectiveness. The Dice Coefficient of Similarity is equal to 0.871 ± 0.060 and the average Hausdorff distance 0.46 ± 0.36 mm. Additionally, to provide a reliable assessment of the proposed method, it was compared with three other methods. The proposed method is robust regardless of the image acquisition mode, spatial resolution and range of image values. The same framework may be applied to further medical applications beyond preoperative planning for partial nephrectomy enabling to visually assess and to measure the pelvicalyceal system by medical doctors.
Go to article

This page uses 'cookies'. Learn more